Service Manuals Automatic Tissue Processor
The support you need to optimize operationsAvantor Services provides a wide range of specialized services and digital solutions to help you solve complex challenges.We’ve built our reputation on consistent, comprehensive mastery of day-to-day operations, allowing lab, clinical, and production environments to focus their high-value resources on core scientific priorities.As our customers’ needs have evolved, so have our capabilities. We have become experts in scientific operations, improving performance with sophisticated solutions and providing guidance on best practices.You can select and customize services for peak efficiency, quality, and accelerated innovation.For more information, call 1.888.793.2300 or email us at. VWR enables the advancement of science by providing high-quality chemicals and services, customized to your product or manufacturing needs.We use operational excellence to deliver solutions that enable research, testing, production, and commercialization across the globe.Our Core Capabilities Include:.
Custom Liquid Manufacturing. Custom Liquid Dosing and Packaging. Custom Powder Manufacturing. Powder Dosing and Packaging. Assembly and FinishingContact VWR Custom Manufacturing Services at 1.800.932.5000 or.
Carousel-type processor has ten 1.8L (60.9oz.) reagent stations and two 1.8L (60.9oz.) wax baths. The tissue basket oscillates up and down in each station at three-second intervals to ensure thorough and even mixing of the reagents and optimum tissue infiltration.
Infiltration time is separately programmable for each station. Up to nine programs may be run with immediate or delayed starting times. When the infiltration time for any particular station is exceeded, a warning message will display, indicating the station number and excess time. Controls are arranged by functionality with an LCD to indicate operational parameters. Reagent container lids have seals to minimize operator exposure to hazardous fumes. Terms & ConditionsThank you for visiting our site.
Automatic Tissue Processor Equipped with latest micro switch mechanism for trouble free performance and convenience in use.Complete with latest built in safety device to protect tissues from 10th stage and 11th to 12th stage that is in wax during electric failure. Today, Milestone is proud to offer innovative solutions in six different fields: Frozen Section, Cytology, Sample Handling, Tissue Processing, Macro Digital and Reagents. All products aim to help patients and to create a better laboratory environment for the medical staff of.
These terms and conditions of use are applicable to the United States, Canada and Puerto Rico websites (“collectively the Web Site”) operated by VWR (the “Company”). If you are accessing the Web Site from outside the United States, Canada, or Puerto Rico, please see the appropriate international website, available at www.vwr.com, for applicable terms and conditions. All users of the Web Site are subject to the following website terms and conditions of use (these “Terms of Use”).
Please read these Terms of Use carefully before accessing or using any part of the Web Site. By accessing or using the Web Site, you agree that you have read, understand and agree to be bound by these Terms of Use, as amended from time to time, as well as the Company Privacy Policy, which is hereby incorporated into these Terms of Use.
If you do not wish to agree to these Terms of Use, do not access or use any part of the Web Site.The Company may revise and update these Terms of Use at any time without notice by posting the amended terms to the Web Site. Oh no the disrupt rapidshare software. Your continued use of the Web Site means that you accept and agree to the revised Terms of Use. If you disagree with the Terms of Use (as amended from time to time) or are dissatisfied with the Web Site, your sole and exclusive remedy is to discontinue using the Web Site.Site UseThe information contained on this Web Site is provided for informational purposes only.
Although the information is believed to correct at the time of publishing, you should make your own determination as to its suitability for your use. Not all of the products or services described in this Web Site are available in all jurisdictions or to all potential customers, and nothing herein is intended as an offer or solicitation in any jurisdiction or to any potential customer where such offer or sale is not qualified.Purchase of Products and ServicesThese Terms and Conditions apply only to the use of the Web Site. Please note, the terms and conditions relating to service, product sales, promotions, and other related activities can be found at and those terms and conditions control any purchases of products or services from the Company.Interactive FeaturesThe Web Site may contain bulletin board services, chat areas, news groups, forums, communities, personal web pages, calendars, and/or other message or communication facilities designed to enable you to communicate with the public at large or with a group (collectively, 'Community Feature').
You agree to use the Community Feature only to post, send and receive messages and material that are proper and related to the particular Community Feature. You agree to use the Web Site only for lawful purposes.A. Specifically you agree not to do any of the following when using a Community Feature:1. Defame, abuse, harass, stalk, threaten or otherwise violate the legal rights (such as rights of privacy and publicity) of others.2. Publish, post, upload, distribute or disseminate any inappropriate, profane, defamatory, infringing, obscene, indecent or unlawful topic, name, material or information.3. Upload files that contain software or other material protected by intellectual property laws (or by rights of privacy of publicity) unless you own or control the rights thereto or have received all necessary consents.4. Upload files that contain viruses, corrupted files, or any other similar software or programs that may damage the operation of another's computer.5.
Intercept or attempt to intercept electronic mail not intended for you.6. Advertise or offer to sell or buy any goods or services for any business purpose, unless such Community Feature specifically allows such messages.7. Conduct or forward surveys, contests, pyramid schemes or chain letters.8. Download any file posted by another user of a Community Feature that you know, or reasonably should know, cannot be legally distributed in such manner or that you have a contractual obligation to keep confidential (notwithstanding its availability on the Web Site).9. Falsify or delete any author attributions, legal or other proper notices or proprietary designations or labels of the origin or source of software or other material contained in a file that is uploaded.10. Misrepresent an affiliation with any person or organization.11. Engage in any other conduct that restricts or inhibits anyone’s use of the Web Site, or which, as determined by the Company, may harm the Company or users of the Web Site or expose them to liability.12.
Violate any applicable laws or regulations or violate any code of conduct or other guidelines which may be applicable for any particular Community Feature.13. Harvest or otherwise collect information about others, including e-mail addresses, without their consent.B.
You understand and acknowledge that you are responsible for whatever content you submit, you, not the Company, have full responsibility for such content, including its legality, reliability and appropriateness. If you post in the name of or on behalf of your employer or another entity, you represent and warrant that you are authorized to do so. By uploading or otherwise transmitting material to any area of the Web Site, you warrant that the material is your own or is in the public domain or otherwise free of proprietary or other restrictions and that you have the right to post it to the Web Site. Additionally, by uploading or otherwise transmitting material to any area of the Web Site you are granting the Company a irrevocable, royalty-free, worldwide right to publish, reproduce, use, adapt, edit and/or modify such material in any way, in any and all media now known or hereafter discovered, worldwide, including on the Internet and World Wide Web, for advertising, commercial, trade and promotional purposes, without additional limitation or compensation, unless prohibited by law, and without notice, review or approval.C. The Company reserves the right, but does not assume any responsibility, to (1) remove any material posted on the Web Site which the Company, in its sole discretion, deems inconsistent with the foregoing commitments, or otherwise inappropriate for any reason; and (2) terminate any user’s access to all or part of the Web Site. However, the Company can neither review all material before it is posted on the Web Site nor ensure prompt removal of objectionable material after it has been posted.
Accordingly, the Company assumes no liability for any action or inaction regarding transmissions, communications or content provided by third parties. The Company reserves the right to take any action it deems necessary to protect the personal safety of users of this Web Site and the public; however, the Company has no liability or responsibility to anyone for performance or nonperformance of the activities described in this paragraph.D.
Abstract
Background:
Surgical pathology is an integral part of diagnosis and management planning in patient care. In the absence of widespread automation, many small laboratories are unable to provide this service due to lack of time. Currently, the shortest processing schedule for formalin-fixed paraffin-embedded tissues is 16 working hours; most small laboratories cannot complete the rapid schedules within the average 8–9 working hours. Thus, the availability of an 8–9 h processing schedule that provide satisfactory results can help many small laboratories in routinely providing surgical pathology services.
Objectives:
To evaluate the effectiveness of a new rapid processing schedule and compare it with two existing rapid processing schedules.
Materials and Methods:
This animal study tested a new rapid processing schedule suggested by authors with overnight preprocessing in 60% isopropyl alcohol followed by an 8 h processing schedule. This was tested and compared with the rapid processing schedules described by Godkar's (11 h) and Bancroft's (2 working days). A routinely used automatic tissue processor long cycle (17 h) was the control. Each schedule was used on 20 tongue specimens. The prepared slides were evaluated for surface area and linear tissue shrinkage, ease of sectioning, quality of hematoxylin and eosin staining, histological appearance and artifacts.
Results:
No statistical differences were found between schedules. Overall total average performance ranking placed Bancroft's schedule as the best with only 27.9% of the sections processed and stained showing any shortcomings, followed closely by the test schedule suggested by authors (28.7%), Godkar's (31.8%) and the automatic processor schedule/control (33.3%).
Conclusion:
The test results indicated that the schedule devised by authors is an effective rapid processing cycle that produces diagnostic quality histological results when compared with other conventional processing schedules for small tissue blocks (average 6 mm × 8 mm).
INTRODUCTION
Rapid diagnosis that enables timely intervention and management planning is largely dependent on an efficient and easily accessible surgical pathology service. Surgical pathology is based on microscopic examination of formalin-fixed paraffin-embedded (FFPE) tissue sections. It is a technology and time intensive service which is currently not provided by many small laboratories. The method depends on preservation of tissues as close to the living state as possible by formalin fixation, followed by a processing cycle aimed at replacing the tissue water (dehydration) with a paraffin miscible agent (clearing) to facilitate paraffin impregnation. As a component of surgical pathology services, there are obvious time constraints on the process.
The rapid processing schedules currently available require a minimum of 16–48 working hours for completion.[1,2,3,4] Processing times that extend beyond the working hours of a laboratory require automation for uninterrupted processing to continue. The high cost of automation and unavailability of uninterrupted power supply in the developing countries makes automation unsuitable for small laboratories. This poses a challenge to these laboratories which have to complete tissue processing during working hours limited to 8–9 h a day. An extensive search of the currently available rapid processing techniques shows that there are no processing schedules that can be completed within 8–9 working hours.
This study was therefore designed to assess the quality of the processed tissues and stained sections by a new rapid manual processing technique devised by the authors for 8 working with two of the shortest processing schedules previously described.
MATERIALS AND METHODS
Study design and sample source
Comparison of processing schedules required fresh samples of equal size and type to avoid variations and technical confounders. This necessitated the design as an animal study. Ethical clearance was obtained from the concerned committee of the institute.
Tissue specimens were sourced from the animals housed in the medical college animal house. Twenty-two Wistar rats nearing the end of their natural lifespan (2–3 years) were selected. The animals weighed 400–600 g and were 2–2½ years in age. They were euthanized humanely by the administration of chloroform inhalant. Tongue was chosen as a soft tissue organ that can provide uniformly firm tissue. The whole mandible with the tongue was dissected with the tongue excised at the base.
Grossing, trimming and fixation
Each tongue (cylindrical in shape) was cut into an average of 4 bits [8 mm × 8 mm × 6 mm] as shown in Figure 1 with sections randomly assigned to the depicted schedules. The natural variation in the size of the animal's tongue meant that some specimens were too small to use. Thus, 22 tongues were included to harvest a total of 80 tissue samples of the desired size. The specimens were fixed in freshly prepared 10% neutral buffered formalin for 24 h.
The schematic representation of grossing of rat tongue
Preprocessing preparation and measurements
After fixation, all specimens were washed with water and pierced through with a thin Begg's wire. Two different sets of measurements were performed for each sample. First, linear length in millimeters was measured as the length of the tissue specimen from the point of entry to the point of exit of the Begg's wire. Second, a two dimension measurement of surface area in square millimeters was done. This was accomplished by morphometric analysis of the specimen images captured with a 3 chip CCD camera on Trinocular stereo microscope (Olympus SZX7, Japan) calibrated for millimeter under × 10 magnification [Figures [Figures22 and and33].
Measurement for linear shrinkage
Measurement for linear shrinkage after processing
Tissue processing
Tissue samples were processed using Godkar's (schedule I) and Bancroft's (schedule II) rapid processing techniques, the test schedule (schedule III) and a routine automatic processor schedule (schedule IV) used as a control [Table 1]. The chemicals were chosen based on a combination of performance, availability, safety and cost.[5,6,7] Thus, isopropyl alcohol, which is easily available to purchase and store, was used for dehydration.[7] Xylene, the main clearing agent has been highly recommended for its penetrative power and ease of removal during impregnation.[7] It is easy to procure, has a good shelf life (not as volatile as chloroform) and possess relatively low toxicity with short-term exposure limit of 150 ppm.[7,8] Acetone is a rapid acting agent that is miscible with both xylene and alcohol. With xylene, acetone achieves complete clearing in a short time without an increase in tissue hardness. It was used as an additional clearing agent in the processing schedule III.
Table 1
Paraffin tissue blocks were prepared and sectioned using soft tissue microtome. Quality of tissue blocks by means of adequate ribbon formation (without tears) as well as folds obtained was observed and recorded during sectioning and mounting [Figures [Figures44–6]. The mounted sections were subsequently stained using hematoxylin and eosin stains. All sections were examined for diagnostic adequacy. Poststaining (PS) surface area of the sections was measured using stereomicroscope [Figure 7]. The dimensional changes relating to shrinkage were calculated for changes in length and surface area measured between preprocessing (PrP) and postprocessing (PoP) and in surface area between PrP and PS. Linear shrinkage was not measured after staining because the two points through which the thin wire passed before processing could not be recognized on the stained slide.
Adequate ribbon formation
Small folds restricted to epithelium and lamina propria (Unstained, x10 under stereomicroscope)
Measurement for shrinkage in cross-sectional surface area after staining
Inadequate ribbon formation
Preservation of tissue architecture by identifying fragmentation, epithelial stripping and irregular voids were examined [Figures [Figures88–10] and recorded after staining by a single observer since there was no expectation of inter-observer variability in this parameter. Remaining parameters were examined by two observers.
Steromicroscopic image showing fragmentation of tissue section (H&E stain, x10 under stereomicroscope)
Steromicroscopic image showing irregular voids seen in the epithelial sections (H&E stain, x10 under stereomicroscope)
Steromicroscopic image showing stripping of epithelium. (H&E stain, x10 under stereomicroscope)
Statistical analysis
Quantitative data are expressed as mean ± standard deviation and number/percentages for discrete data. Shrinkage was calculated as the mean difference between PrP and PoP or PS. One-way ANOVA was used for multiple group comparisons followed by Tukey's test for group-wise comparisons. Chi-square test was used for analyzing categorical data. Interobserver reliability was tested by Kappa measure of agreement. P ≤ 0.05 was considered statistically significant.
RESULTS
Effect of processing schedules on shrinkage
Tissues processed in all the schedules showed some amount of linear shrinkage [Table 2]. The mean percentage of the shrinkage ranged from 10.51% in the schedule II to 14.08% in schedule IV. The difference between the rapid processing techniques was insignificant.
Table 2
Postprocessing linear shrinkage (single dimension) - comparison of preprocessing and postprocessing length of specimens
PoP surface area shrinkage [Table 3] ranged from 21.94% to 29.36% and from 10.91% to 13.33% PS [Table 4], with schedule II showing the least and schedule IV the most shrinkage. Summary of the mean percentages [Table 5] calculated from overall shrinkage values demonstrated a range of 14.4–19% shrinkage of specimens by the Schedules and showed schedule II to have the least overall shrinkage followed by schedule III, schedule I and schedule IV.
Table 3
Postprocessing surface area shrinkage (two-dimension) - comparison of preprocessing and postprocessing specimen surface area
Table 4
Poststaining surface area shrinkage (two-dimension) - comparison of preprocessing and poststaining specimen surface area
Table 5
Ease of sectioning (with Chi-square or χ2 values and kappa statistics values for inter observer variability where applicable)
Effect of processing schedules on ease of sectioning and quality of sections
None of the schedules produced inadequate ribbons or an inadequate consistency for cutting. The schedules showed slight variation in their performance in terms of section tears, folds and difficulty in section handling [Table 5]. The overall performance of the schedules also found them in a narrow range of performance with the best schedule being schedule III with 48.3% total score in terms of shortcomings, followed by schedule II at 50%, schedule I at 51.7% and schedule IV at 56.7%.
Effect of processing on staining
Sections from all schedules were of acceptable diagnostic quality. However, some degree of cellular shrinkage, differences in staining, loss of detail and artifacts was seen in sections processed by all schedules [Table 6]. The overall range [Table 7] of performance was narrow and no significant differences were found between the resulting stained sections. Schedule II performed the best with only 19.4% of the stained sections having any shortcomings, followed by schedule III with 20%, schedule I with 25.6% and schedule IV with 24.4%.
Table 6
H and E staining (with Chi-square or χ2 values and kappa statistics values for inter observer variability wherever applicable)
Table 7
The overall performance based on total average performance in each category showed Bancroft's schedule (II) as the best with only 27.9% of the sections processed and stained showing any shortcomings, followed closely by the test schedule suggested by authors’ (28.7%), Godkar's schedule (31.8%) and the automatic processor schedule/control (33.3%).
DISCUSSION
The practice of anatomical pathology and, therefore, surgical pathology is widely dependent on the study of FFPE tissue sections. Manual processing of tissues in small resource-limited laboratories can be challenging. It requires schedules that can be completed within the working hours of the laboratory without compromising on the quality of the stained sections. A number of rapid processing protocols for FFPE have been described in the literature. While widely accepted by pathologists around the world, even the shortest of these methods require 11 working hours. This study compared a new schedule (III) that required 8–9 working hours with two standard rapid processing schedules (I and II) and a routinely used automatic processor long cycle protocol (IV) as control. The tissues processed were screened for the adequacy of sections for diagnosis and examined for degree of shrinkage in length and surface area, ease of sectioning, preservation of architectural and cytological structure, staining properties and artifacts.
Godkar's rapid processing schedule (schedule I) begins dehydration at the highest initial concentration of 80% alcohol among the tested schedules and maintains the tissue at 100% alcohol for 3 h. The tissues then go through a 2 h clearing and 3 h impregnation cycle. Bancroft's schedule (II) begins with immersion in 70% alcohol. It goes on to have the longest dehydration cycle of 7 stations in alcohol (approximately 19½ h) and the longest stay in 100% alcohol the tissues then go through 3½ h clearing and 4½ h impregnation cycles. The third schedule introduced by the authors (schedule III) begins with overnight PrP dehydration in 60% alcohol followed by 3 h of progressive dehydration, ending with an hour in 100% alcohol. This is followed by 3 h clearing (in 50:50 mixture of xylene and acetone-1 h and xylene-2 h) and 4 h wax impregnation. The schedule IV was the routinely used automatic processor schedule. It starts with 60% alcohol, and then progresses through a total 6 stations in alcohol for a total dehydration time of 9 h that includes 3 h in 100%. It is then followed by the longest clearing and impregnation cycles of 4 h each.
Shrinkage is one of the most significant tissue changes in FFPE tissues. All the schedules tested in this study caused some shrinkage in the tissues. The amount of linear shrinkage in the test schedule III (12.95%) was intermediate between schedule I (13.68%) and schedule II (10.51%) with no significant differences between these schedules. A significant difference was found between schedule II and IV (14.08%); this difference did not relate to the performance of the test schedule. All schedules caused PoP and PS shrinkage in surface area. PoP shrinkage (21.17–29.36%) was larger than PS shrinkage (10.91–13.33%). The differences in the surface area shrinkage between the schedules were not statistically significant. The overall score based on linear and surface area shrinkage showed least shrinkage by schedule II (14.4%), followed by schedule III (17.8%), schedule I (17.8%) and schedule IV (19%). Paraffin solidification can cause postfixation shrinkage of up to 15% in FFPE tissues[9,10] and could have been contributory to this level of shrinkage. The overall shrinkage volume PS was lesser than PoP shrinkage. Thus, some quantum of PoP shrinkage was reversed during staining; this may be due to removal of paraffin and rehydration of sections during the staining process.
The schedules did not show any significant differences in the ease of sectioning and quality of sections produced. None of the schedules showed inadequate ribbon formation and cutting consistency. Schedule III (5%) showed the least amount of tears and schedule II (20%) the highest amount while schedules I and IV (15% each) showed an intermediate amount of tears. The higher number of tears in schedule II tissues might have been caused by longer dehydration. Optimal dehydration is achieved by removal of interstitial water. Excessive dehydration causes a progressive elimination of bound water molecules from the tissue. The removal of these molecules, which are parts of structural configuration of the amino acids, makes the over dehydrated tissues more dry and brittle. These tissues are difficult to manage easily and are damaged during microtomy.[11]
Both small (35%) and large folds (25%) were least in schedule I and most in schedule IV (55% and 35%), respectively. Other two schedules were intermediate between these. Folds may be caused by remaining traces of processing fluid in the specimen making the specimen hydrophilic, with rapid water absorption with the hydrophobic wax around causing tissue folds in water-bath.[12,13] Thus, the short processing time in schedule I as against the long time in schedule IV can explain the distribution of section folds in different schedules.
Schedules III and II (15% each) showed the least number of sections that were difficult to handle while schedules IV and I (35%) did not perform, as well. This ranking is not in agreement with previously reported increasing tears with increasing dehydration.[11]
Overall score in ease of sectioning and adequacy of sections showed the schedules to be marginally different. Schedule III was the best with only 48.3% of sections showing any defect. Schedule II was the second with 50%; schedule I was the third with 51.7% and schedule IV performed the worst at 56.7%. While the differences are not significant, they do demonstrate that the three rapid processing schedules provide similar quality of sections, and the excessively long cycle chosen for the automatic processor leads to poor quality.
The schedules showed nonsignificant differences in the microscopic quality of the stained sections. While the schedules performed variably under each criterion, the best overall performance was by schedule II with only a total mean of 19.4% of the stained sections showing any shortcoming, followed by schedules III (20%), IV (24.4%) and I (25.6%).
Cell shrinkage followed a pattern similar to overall shrinkage with the least quantity of shrinkage in schedule II (10%) and the most in schedule IV (25%). Schedules I (15%) and III (20%) occupied the second and third place, respectively. Cellular shrinkage has been linked to overall length of stay in Xylene.[8] Schedules I, II and III had varying xylene exposure times of <4 h which did not correlate with the cell shrinkage values. Thus, it may be assumed that other unknown factors may be responsible for shrinkage.
Cytoplasmic details were the least affected by schedule II and III (0% each) followed by schedule IV (10%) and schedule I (15%). Over stained or dark nuclei were found to be equal and least common in schedule I and II (25% each), followed by an equal amount in schedule III and IV (35%). Dark or unclear nucleoli were least in schedule II (20%), followed by an equal number in schedule I and III (30%) and a maximum number in schedule IV (35%). Overall suboptimal staining (over/under staining) was least in schedule IV (5%), followed by schedules III (15%), I (20%) and II (25%). Over-stained or darkly stained sections are linked to conformational tissue changes that result from excessive dehydration. They lead to the formation of stable proteins, into which dye aggregates get locked.[14] A literature search did not find any currently accepted processing linked causes for under-staining.
Lack of clarity of chromatin distribution was the least in schedule II (15%), followed by schedule III (20%), IV (25%) and I (35%). Increased xylene exposure has been linked to reduced nuclear chromatin details and unclear nucleoli.[8] This study showed a poorer performance by schedule I with the shortest Xylene exposure than schedule IV with the longest exposure, thereby contradicting the previous findings.
Sections showed no artifacts in schedule III while schedules II and IV (5% each) and schedule I (20%) showed some artifacts.
The overall performance of the schedules based on all the parameters showed them to be closely comparable. All the sections by all the schedules were of sufficient diagnostic quality. Bancroft's rapid processing schedule was the best with only 27.9% of the sections processed and stained showing any shortcomings, followed closely by the test schedule suggested by authors (28.7%), Godkar's schedule (31.8%) and the automatic processor schedule/control (33.3%).
This overall result and the lack of any significant differences in the performance of the rapid processing schedules (I, II and III) confirm that the test schedule suggested in this study can be advantageously used for rapid processing of tissues in small laboratories that depend on manual processing, without any loss of quality.
Additional experience with the schedule may be needed to validate it further. Future studies combining this schedule and microwave use may further reduce the overall time.
CONCLUSION
The rapid processing schedule suggested by this study is an effective method for FFPE tissues. It produces pre- and post-staining sections that are comparable with those produced by Bancroft and Godkar's rapid processing schedules. The suggested rapid processing schedule can be effectively used by small laboratories in providing surgical pathology service.
The new technique can be beneficially used in the short cycle of the automatic processor to reduce both material cost and time.
Conflicts of interest
There are no conflicts of interest.